CC_a039_internalModuleOverTemp
Wall connector real-time processor is too hot
Real-time processor exceeds 85C
Real-time processor cools to below 65C
Charging will be interrupted and one red blink on LEDs
info from manualCC_A017
Contactor detected as closed when it should be open
info from manualCC_A010
Wall connector detects voltage on the contactor output when it should be open
User resets by cycling cable, reset button, or power cycle
Wall connector will not operate and there is a potential hazardous voltage present on the charge handle
info from manualCC_A016
Wall connector internal voltage reference is out of acceptable range
Internal voltage reference leaves acceptable range
Internal voltage reference enters acceptable range
AC RMS input voltage is too high
info from manualCC_A007
AC RMS input voltage exceeds 320 V RMS for NA or 290 V RMS for EU/CN for more than 2 seconds
AC RMS input voltage falls below 310 V RMS for NA or 280 V RMS for EU/CN for more than 2 seconds
Wall connector will not allow charging while the input voltage is too high
PCBA temperature exceeds threshold
PCBA temperature falls below threshold
Charging rate will be reduced by 50%
Wall connector is configured as a slave but no master was detected
info from manualCC_A021
Wall connector is configured as a slave but no master is present on the sharing network
Wall connector is reconfigured or a master becomes present on the sharing network