PCS_a042_dcdcEnableLineMismatch
PCS DCDC hardware enable line does not match CAN signal
DCDC converter detects that sensed enable hardline state does not match state reported on CAN for more than five seconds
DCDC converter detects that sensed enable hardline state matches state reported on CAN for more than one second
AC charging is stopped because DCDC is too hot
DCDC converter temperature exceeds threshold for more than five seconds while AC charging is active
DCDC converter temperature is below clear threshold for more than twenty seconds
Charger output voltage sensor mismatches high voltage processor's sensed value on CAN
Charger output voltage sensor mismatches high voltage processor's sensed value on CAN for more than three seconds
Charger output voltage sensor value matches high voltage processor's sensed value on CAN for more than 500ms
PCS charging input RMS over-voltage
Charger RMS AC input voltage exceeds overvoltage threshold