PCS_a075_hvBusDischargeTimeout
PCS DCDC timed out when attempting to discharge HV bus
DCDC converter timed out when attempting to discharge HV bus
Inability to perform vehicle precharge, CHAdeMO and GB DC compatibility may be impacted
Input voltage measurement changed too much between switching cycles (only active in phase A)
Charger AC input voltage changed too much between switching cycles
Charger input line over voltage
Charger AC input voltage peak level exceeds maximum input voltage peak threshold
Reduced AC charge rate or inability to AC charge, possibly due to incompatible grid
PCS DCDC temperature sensor is reporting irrational value
DCDC converter temperature is outside expected range for more than one second
DCDC converter temperature is within expected range
Reduced available DCDC output power
PCS DCDC HV bus voltage reading differs from HVP HV bus voltage reading by an excessive amount
DCDC converter high voltage bus voltage sensor mismatches high voltage processor's sensed value on CAN for more than three seconds
DCDC converter high voltage bus voltage sensor matches high voltage processor's sensed value on CAN for more than 500ms