TAS_a076_overVoltage5VOffBoard
Off board 5V switched supply is measured to be over 5.5V.
Front left air valve detected open circuit.
Front left air valve commanded on but no electrical current measured.
An issue is indicated from the NVRAM Manager.
Record not found, CRC mismatch, Version mismatch, Version upgrade.
Ride height calibration, target suspension level, crash status, or learned VIN may be lost.
Pressure sensor signal voltage too low; likely disconnected.
Pressure sensor signal received is too low.
Pressure sensor signal received is in range.
One or more CAN messages from DI are not being received by the ECU.
One or more CAN messages from DI are not being received by the ECU (missing, bad RX rate, or invalid checksum/counter).
Successful reception of all RXd CAN messages from DI.
Air suspension functionality may be reduced. Excessive leveling corrections may occur and system may not lower suspension at higher speeds.
No valid ride height sensor calibrations have been saved to the ECU.
Received ride height sensor calibration values are inside of allowable range.
Air suspension will only level upon manual requests. Auto leveling of suspension is disabled.

file create by H+ 2022 v0325 updater.store