VCFRONT_a459_thermalFillAndDrive
The thermal system is currently being filled while the vehicle is in drive
The thermal fill drain routine is stopped
The voltage on the 12V battery went below the minimum limit
12V Battery Voltage below 10.5V for 5 seconds or 12V Battery Amp Hours below -27Ah for 1 hour.
12V Battery Voltage no longer below 10.5V.

file create by H+ 2022 v0325 updater.store